Direct Cooling Containerized Data Center With Flexible Expansion

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Direct Cooling Containerized Data Center With Flexible Expansion

Brand Name : COOLNET

Model Number : CBMC

Certification : CE,ISO

Place of Origin : CHINA

MOQ : 1unit

Price : 10000-50000USD per unit

Payment Terms : L/C, T/T

Supply Ability : 50 unit per month

Delivery Time : 20-40 days

Packaging Details : FCL

Model : CBMC

Miner type : Antminer Avalon

Power input : 380V, 220v, 3phase

Maximum capacity : 400 units miner

Cooling : Fan cooling

Size : 20FT 40FT

Contact Now

Containerized Data Center With Flexible Expansion And Direct Cooling

Product Introduction


In contrast to the traditional data center construction mode based on the building body, the container-level data center takes the commercial standard container as the carrier of the data center and integrates all systems such as cabinets, power distribution, refrigeration, integrated wiring, monitoring and management, fire protection and security, etc. It adopts the production mode of factory prefabrication and pre-commissioning, transports the container as a whole to the deployment site by land or sea, and then builds it on site in the way of "building blocks". It can be built in the way of "building blocks" and can be operated independently by accessing utility power, network and water source, thus making the deployment of data center more mobile and flexible.
Direct Cooling Containerized Data Center With Flexible Expansion

Feature

Direct Cooling Containerized Data Center With Flexible Expansion
  • High modular degree, simple structure, convenient for transportation, installation and maintenance;
  • According to the properties of the selected batteries, choose the specialized Intelligent BMS;
  • The system is equipped with local and remote monitor system, implementing real-time online control;
  • Bilingual contrast
  • Adopt air cooling mode, optimize the air distribution, implement intelligent control, save temperature control energy consumption, temperature field is uniform ;
  • With complete safety protection measures to ensure operation personnel and energy storage system safe and work reliably.
  • As per the customer requirement and load character provide the custom design solution,
  • Base on the system requirement, adopt the specialized energy storage battery Lead acid, Gel, Lead carbon or lithium ion battery, configure energy storage units flexibly;

Advantage

Customized Engineering, Rapid Deployment
Modular data centers can be deployed very quickly, with traditional civil buildings replaced by light steel structures or storage warehouses, with construction cycles typically taking only a few weeks, compared to months, or even years, to build a traditional data center. Also, with modular container products, product quality can be fully guaranteed.


Low cost
Low-cost building materials and construction methods reduce costs for users of containerized data centers and prefabricated units. In some countries or regions, adopters also benefit from tax and regulatory incentives. Hybrid customers (using containerized data centers in traditional data centers) share data center space with other data centers, resulting in cost savings.


Green and Energy Efficient
Containerized data centers are manufactured in T-factories, with more compact interiors and closed hot and cold aisles for high cooling efficiency.


Easy to expand
If needed, more space can be added, as shown by adding containerized data centers, prefabricated units or building volumes.

Direct Cooling Containerized Data Center With Flexible Expansion

Technical Parameter

PRODUCT PARAMETERS ICDC20 ICDC40
Container Size 20'HQ 40'HQ
Rack Specification 600*1000*2000 600*1000*2000
Single Rack Capacity 42U 42U
Rack Quantity 4pcs 4pcs
Single Rack Max. Capacity 6KW 6KW
IT Equipment Total Capacity 24KW 48KW
UPS 25KVA*2
N+1 Modular UPS
25KVA*3
N+1 Modular UPS
Battery Back-up Time 10Minutes 10Minutes
Cooling Pattern Inrow Air Condition Inrow Air Condition
Monitoring system YES YES
Door Security System YES YES
Fire alarm and gas fire extinguishing system YES YES
Video Monitoring System YES YES
EPO YES YES
Transportability Support Support
Stackable Support Support
Application Outdoor Type Outdoor Type
Diesel Generator Module Extra position Extra position

Certification

Direct Cooling Containerized Data Center With Flexible Expansion

Case

Direct Cooling Containerized Data Center With Flexible Expansion


Product Tags:

Containerized Data Center Flexible Expansion

      

Direct Cooling Containerized Data Center

      

Direct Cooling Container Data Center

      
Best Direct Cooling Containerized Data Center With Flexible Expansion wholesale

Direct Cooling Containerized Data Center With Flexible Expansion Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)